The **MITSUBISHI A1SY42** is an **I/O module** designed for the **MELSEC A Series PLC**, enabling the PLC to interface with external devices via **analog inputs...

Need More Details?
If you’d like to check stock availability, request the latest price, or view more product images, simply click the "Request for Price" button and our team will assist you promptly.

The **MITSUBISHI A1SY42** is an **I/O module** designed for the **MELSEC A Series PLC**, enabling the PLC to interface with external devices via **analog inputs and outputs**. The **A1SY42** provides high-precision analog signal processing, ideal for applications that require the handling of continuous signals like temperature, pressure, or flow. It supports **voltage** and **current** signal types for both input and output channels, making it a versatile addition to the **MELSEC A Series PLC** in industrial control and automation systems.

### Key Features and Specifications of **MITSUBISHI A1SY42**:

1. **Module Type**:
   - The **A1SY42** is an **analog I/O module** designed for the **MELSEC A Series PLC**.
   - It provides a flexible solution for processing analog signals, enabling the PLC to handle a variety of industrial applications that require analog control and monitoring.

2. **I/O Channels**:
   - The **A1SY42** provides **4 analog input channels** and **4 analog output channels** (4 channels each for input and output).
   - The module supports a variety of **voltage** and **current** signal ranges, such as **0-10V**, **4-20mA**, and other standard industrial analog signal formats.
   - The dual function (input/output) allows the PLC to both receive analog signals from sensors or transducers and send analog control signals to actuators, valves, or other devices.

3. **Signal Conversion**:
   - The **A1SY42** features high-resolution **Analog-to-Digital (A/D)** and **Digital-to-Analog (D/A)** conversion, with **12-bit resolution** for both input and output channels.
   - The **A/D conversion** allows the PLC to process continuous analog signals by converting them into digital data for decision-making and control.
   - The **D/A conversion** ensures that the PLC can send accurate analog control signals to connected devices for precise actuation.

4. **Communication**:
   - The **A1SY42** module communicates directly with the **MELSEC A Series PLC** via the **PLC backplane**, ensuring fast data transfer and minimal wiring.
   - It integrates seamlessly into the **MELSEC A Series** system without the need for additional communication modules or networks.

5. **Modular Expansion**:
   - The **A1SY42** module is designed for easy installation onto the **MELSEC A Series rack**, expanding the PLC’s analog I/O capabilities without requiring additional space or external devices.
   - Multiple **A1SY42** modules can be used in a system to add more analog channels, making it scalable for different application requirements.

6. **High-Speed Processing**:
   - The **A1SY42** is capable of fast signal processing, providing **real-time control** for applications that require rapid feedback based on analog signals.
   - This module is ideal for controlling continuous processes where precise analog data must be quickly read, processed, and used to adjust outputs accordingly.

7. **LED Indicators**:
   - The **A1SY42** module features **LED indicators** for each input and output point, providing visual feedback on the status of the analog signals.
   - The LEDs display information such as **power status**, **signal status**, and any potential **error conditions**, aiding in troubleshooting and maintenance.

8. **Applications**:
   - **Industrial Automation**: The **A1SY42** is used in various industrial automation systems where analog signals from sensors need to be monitored and processed. It can handle inputs like temperature sensors, pressure transmitters, and flow meters.
   - **Process Control**: Ideal for controlling continuous processes, such as controlling the speed of motors, adjusting the flow of liquids, or regulating temperature in furnaces, ovens, or HVAC systems.
   - **Machine Control**: It can be used in machine control applications where both monitoring and control of analog signals are required for precise machine operation.

9. **Software Support**:
   - The **A1SY42** is configured and programmed through **Mitsubishi’s GX Developer** or **GX Works** software.
   - The software provides easy-to-use tools for defining analog signal ranges, scaling, and programming the logic required for analog signal processing in the PLC system.

10. **Installation**:
   - The **A1SY42** is installed directly into the **MELSEC A Series PLC rack**, requiring no additional wiring or external power supplies beyond the PLC’s backplane.
   - Once installed, the module is powered by the PLC’s internal power supply, simplifying the installation process and reducing the need for separate power sources.

### Technical Specifications:

- **Type**: Analog I/O Module for **MELSEC A Series PLC**
- **For Use With**: **MELSEC A Series PLCs** (A1S, A1SJ, A1SJH, etc.)
- **I/O Configuration**: 4 analog inputs and 4 analog outputs (8 total channels)
- **Signal Types**: Voltage (e.g., 0-10V) and current (e.g., 4-20mA) for both inputs and outputs
- **Analog-to-Digital (A/D) Conversion**: 12-bit resolution
- **Digital-to-Analog (D/A) Conversion**: 12-bit resolution
- **LED Indicators**: Power, Signal status, and Error indicators
- **Software Support**: Configured via **Mitsubishi GX Developer** or **GX Works**
- **Power Supply**: Powered via the **PLC backplane**
- **Operating Environment**: Typically **0°C to 55°C** temperature range
- **Mounting**: Mounted directly onto the **MELSEC A Series rack**
- **Installation**: Plug-in module, no external wiring required for power

### Summary:

The **MITSUBISHI A1SY42** is an **analog I/O module** designed to expand the analog signal handling capabilities of the **MELSEC A Series PLC**. Offering **4 analog inputs** and **4 analog outputs**, it provides high-precision **12-bit A/D and D/A conversion** for both voltage and current signals. This module is ideal for industrial applications like **process control**, **machine control**, and **industrial automation** that require continuous signal processing. With its easy integration into the **MELSEC A Series** system and programming support via **Mitsubishi GX Developer** or **GX Works**, the **A1SY42** is a powerful solution for managing analog signals in real-time.

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.