The **MITSUBISHI FX0N-16-EX-ES** is an **expansion I/O module** designed for use with the **MELSEC FX0N series PLC**. This module allows for the addition of additional I/O points to expand the input and output capabilities of the **FX0N PLC** system, making it suitable for a wide range of industrial automation applications.
### Key Features and Specifications of **MITSUBISHI FX0N-16-EX-ES**:
1. **Module Type**:
- The **FX0N-16-EX-ES** is an **expansion I/O module** for the **MELSEC FX0N series PLC**.
- It provides **16 additional digital I/O points**, enabling the PLC to interface with more external devices, such as sensors, actuators, switches, and other control devices.
2. **I/O Configuration**:
- The module features **16 I/O points** (16 digital inputs and outputs) that allow the **FX0N PLC** to control a variety of devices that require on/off (discrete) signals.
- These I/O points are used to interface with devices like push buttons, limit switches, proximity sensors, and relays, supporting industrial applications in control systems.
3. **Input/Output Types**:
- The **FX0N-16-EX-ES** provides both **digital inputs** (for receiving signals from field devices) and **digital outputs** (for sending control signals to devices).
- The module uses **transistor-type outputs** and **24V DC** input voltage, commonly used in industrial control systems.
4. **Modular Expansion**:
- The **FX0N-16-EX-ES** is designed to expand the **I/O capacity** of the **MELSEC FX0N series PLC** by adding more I/O points.
- The module can be connected to the **FX0N PLC** through the **PLC backplane**, and multiple modules can be added if more I/O points are needed.
5. **Communication**:
- The module connects directly to the **FX0N series PLC** using the **MELSEC FX0N series backplane**, ensuring fast and reliable communication between the PLC and the expansion module.
- There are no additional communication cables or networking required for the expansion, making installation straightforward.
6. **Compatibility**:
- The **FX0N-16-EX-ES** module is specifically designed to work with **MELSEC FX0N PLCs**, providing seamless integration with the PLC’s CPU and other I/O modules.
- It supports the same programming and configuration environment as the base **FX0N PLC**, such as **Mitsubishi GX Developer** or **GX Works2** software.
7. **Installation**:
- The **FX0N-16-EX-ES** module is **easily installed** onto the **MELSEC FX0N PLC rack**, directly connecting to the PLC without the need for additional external wiring for power.
- The module is designed for **plug-and-play** installation, making it quick and simple to integrate into existing systems.
8. **LED Indicators**:
- The module features **LED indicators** for each I/O point, displaying the status of inputs and outputs, such as ON/OFF or error conditions.
- These LEDs assist in monitoring and troubleshooting the system, providing real-time status feedback.
9. **Applications**:
- **Industrial Automation**: The **FX0N-16-EX-ES** is used in **factories, production lines**, and **machine control** applications that require additional I/O capacity for discrete control tasks.
- **Process Control**: It can also be used in **process control** systems to manage discrete signals from limit switches, sensors, or other on/off devices.
- **Building Automation**: The module is ideal for controlling equipment like **lighting**, **HVAC systems**, and other electrical devices in **building automation** systems.
10. **Software Support**:
- The **FX0N-16-EX-ES** module is configured and programmed using **Mitsubishi GX Developer** or **GX Works2** software.
- Users can assign I/O points to the PLC program and configure the logic that controls the external devices connected to the module.
### Technical Specifications:
- **Type**: Expansion I/O Module
- **For Use With**: **MELSEC FX0N PLCs**
- **I/O Configuration**: 16 I/O points (16 digital I/O)
- **I/O Types**: Digital Inputs and Outputs (Transistor Type, 24V DC)
- **Communication**: Direct connection to the **FX0N PLC backplane**
- **LED Indicators**: Real-time status for I/O points (Power, I/O status, Error)
- **Software Support**: Programmed via **Mitsubishi GX Developer** or **GX Works2**
- **Power Supply**: Powered via **PLC backplane**
- **Operating Environment**: Typically **0°C to 55°C** temperature range
- **Mounting**: Mounted directly onto the **FX0N series rack**
- **Installation**: Plug-in module, no external wiring required for power
### Summary:
The **MITSUBISHI FX0N-16-EX-ES** is an **expansion I/O module** designed for the **MELSEC FX0N PLC**, providing an additional **16 I/O points** (digital inputs and outputs). It is ideal for expanding the **I/O capacity** of the **FX0N PLC** in **industrial automation**, **machine control**, and **process control** applications. With its **transistor-type outputs**, **24V DC input** voltage, and **plug-and-play** installation, the **FX0N-16-EX-ES** module offers a cost-effective and scalable solution for systems requiring additional I/O points. It integrates seamlessly into the **MELSEC FX0N** environment and can be easily configured using **Mitsubishi GX Developer** or **GX Works2** software.